Orthodynamics CUT Femoral Neck Prosthesis | Used in Total hip replacement | Which Medical Device

CUT Femoral Neck Prosthesis

Added Mar 29, 2011

Manufactured by Orthodynamics

Editor Rating

info

User Rating

info
Add your Rating

Description

From Which Medical Device

The CUT femoral neck endoprosthesis is a short stem device with a modular dual cone proximal component that allows the selection of different offsets and versions once the stem has been implanted. The implant is made from CoCrMo alloy and has a macroporous structure. The stem is curved at the tip, to sit against the lateral cortex of the femur, and appears to better load the proximal femur than other more conventional stems (1).

The results of this implant have been variable.  Steens et al quote a 5 year survival rate of 98% at an average of 6.6 years, but reported technical issues with this implant include valgus/varus malalignment, with undersized components tending to drift into valgus, and occasional revision required because of lack of offset (2).  Other authors have reported much lower survival; Ender et al reported a 5 year survival of 89%, and Ishaque et al reported 8 year survival of 49.6% (3,4).

For further information on short femoral stems, read our article on What's Available in Short Stem Hip replacements.

References:

(1) Decking R , Rokahr C , Zurstegge M, Simon U, Decking J. Maintenance of bone mineral density after implantation of a femoral neck hip prosthesis. BMC Musculoskeletal Disorders 2008, 9:17doi:10.1186/1471-2474-9-17

(2) Steens W, Skripitz R, Schneeberger AG, Petzing I, Simon U, Goetze C.
[Cementless femoral neck prosthesis CUT--clinical and radiological results after 5 years]. [Article in German]. Z Orthop Unfall. 2010 Aug;148(4):413-9. Epub 2010 Aug 16. 

(3) Ender SA, Machner A, Pap G, Hubbe J, Grashoff H, Neumann HW.
Cementless CUT femoral neck prosthesis: increased rate of aseptic loosening after 5 years. Acta Orthop. 2007 Oct;78(5):616-21.

(4) Ishaque BA, Donle E, Gils J, Wienbeck S, Basad E, Stürz H.[Eight-year results of the femoral neck prosthesis ESKA-CUT]. [Article in German]. Z Orthop Unfall. 2009 Mar-Apr;147(2):158-65. Epub 2009 Apr 8.

Have you used this device?

Your opinion matters to others - rate this device or add a comment

WhichMedicalDevice is a FREE resource created by clinicians for clinicians.

Registration is free and gives you unlimited access to all of the content and features of this website.

Find out more...

Please sign in to view this content...

I have forgotten my password
Not a Member?

Registration is free and gives you unlimited access to all of the content and features of Which Medical Device. Find out more...

Why Register

Which Medical Device is a community of clinicians sharing knowledge and experience of the devices and procedures we use on a daily basis. We ask that our members register with us so that we can maintain the unbiased and independent nature of our content. Registration is quick and free.

We do not make your details available to any third parties nor do we send unsolicited emails to our members. You can read our Privacy Policy here.