Angio-seal is a medical device indicated for use in closing and reducing time to hemostasis at the femoral arterial puncture site in patients who have undergone diagnostic angiography procedures or interventional procedures (minimal artery diameter of 4mm). The 6F Angio-Seal device is for...
read full descriptionAt CIRSE 2014, Terumo annunced ?the launch of AZUR CX. ?They said that the soft .018? detachable coil has been optimised to deliver Best-in-Class, cross-sectional coverage. ?It is a complex-shaped, bare platinum coil with an inner core of hydrogel that expands from the inside out. ?The unique...
read full descriptionThe AZUR CX Peripheral Coil System from Terumo is a newer version of the manufacturer's AZUR Peripheral Hydrocoil System . Terumo say that this is a unique balance of coil design and Hydrogel technology for a wide range of procedures. It is available in 2mm and 3mm sizes for small vessel...
read full descriptionThe biopearl from terumo is said to be the worlds first resorbable drug eluting microsphere. The idea is to deliver the drug to the TACE target lesion then allow gradual restoration of blood flow to allow repeated lesion access. They are compatible with doxorubicin, epirubicin and...
read full descriptionThis aspiration catheter from Terumo comes in 6, 7 and 8F sizes with lumens 1 to 1.42m diameter. It is rapid exchange requiring an 0.014 inch guide wire with a usable length of 140cm.
read full descriptionThe Femoseal by Terumo is a closure device using 3 bioabsorbable components. 2 of these are polymer dics with an inner disc deployed inside the vessel and an outer disc on the outer wall of the vessel with an absorbable locking suture joining the two. Terumo quote a median time to...
read full descriptionThe Glidecath 4 Fr Hydrophilic Coated Catheter has a hydrophilic coated distal tip (15 cm) for smooth passage through tortuous vasculature. The device has a double-braided stainless steel mesh middle layer, a nylon-rich polyurethane inner layer and can accommodate...
read full descriptionThe Terumo Glidewire has a hydrophilic coating for smooth, rapid movement through tortuous vessels and crossability over difficult lesions.
read full descriptionAn excellent addition to any IR departments’ shelf, the Terumo Glidewire Advantage is a combination wire consisting of a distal 25cm hydrophilic component fused with a stiff proximal shaft (resulting in increased pushability) with spiral PTFE coating.
read full descriptionThe GT wire from Terumo is a micro guidewire with hydrophilic coating and a variety of different shaped ends. 45/90 degrees, J tipped, and double angled 90 plus 150 degrees. The wire is nitinol with a hydrophilic coating and a distal gold coil at the tip to aid visibility.
read full descriptionHiryu is a percutaneous transluminal coronary angioplasty (PTCA) dilation catheter used for angina and other treatment. According to the manufacturer, it has high pressure resistance (to enable the widening of hardened blood vessels) and capability in reaching peripheral blood vessels.
read full descriptionThese are polyethylene glycol (PEG) embolisation microspheres that can be loaded with a variety of chemotherapeutic drugs: doxorubicin, irinotecan, idarubicin and epirubicin. Terumo claim enhanced suspension characteristics and tight calibration of size. They can absorb the following:...
read full descriptionAn interesting device that can be switched between power modulation or temperature modulation modes. This presumably varies between the different types of ablation needle. The power modulation mode likely relies on impedence feedback such as in the cooltip device from Medtronic ad RF 3000...
read full descriptionThe Pinnacle Destination Guiding Sheath consists of a guiding catheter and an introducer sheath. The variety of different curves allow access across the aortic bifurcation, to the renal arteries and other areas giving good support for selective catheters for stenting and embolisation. Two valve...
read full descriptionAt CIRSE 2014, Terumo announced the launch of the Progreat Double Marker, available in 2.4Fr and 2.8Fr version. They said that the device has the unique navigability and torquability of the usual Progreat and two markers that provide excellent visibility.
read full descriptionLonger lengths for radial procedures 150cm and 175cm catheter lengths facilitate radial UFE and PAE procedures Master Ultra Branch Selectivity Designed to treat challenging anatomies, thanks to ultra-branch selectivity1 combined with anti-kick back1 and an anti-kinking1 high...
read full descriptionHyperselective hydrophilic braided radiopaque microcatheters for peripheral and extracranial procedures. This is often our first choice of microcatheter. The end can be bent and a limited amount of torque can be applied for really tricky angulations. Some versions come with their own wire....
read full descriptionQuiremScout Microspheres Visualize SIRT success from the start The first and only CE-marked SIRT work-up product that utilizes the same technology (Holmium-166 microspheres) as the therapeutic microspheres, to optimize patient selection and advance treatment planning. Characteristics...
read full descriptionTerumo’s M Coat sheath offers smoother insertion and removal and minimizes the problem of spasm, making it ideal for routine TRI procedures. Retrieving the M Coat sheath from the radial artery requires only half the force compared to conventional uncoated sheaths. This helps minimizing...
read full descriptionThis is Terumo's carotid artery stent system. They claim it has the flexibility of an open cell design while outperforming the benefits of a closed cell stent. The stent is constructed from a double layered nitinol mesh and is a 5F rapid exchange system over a 0.014 inch wire. The stent is...
read full descriptionRyujin is a high performance semi compliant balloon catheter utilizing the latest technology developed by Terumo. It combines innovative shaft construction, new balloon design, with low profile for improved crossability while maintaining the trackability.
read full descriptionAccording to the manufacturer, the Ryujin Plus rapid exchange balloon catheter is designed for percutaneous transluminal coronary angioplasty for improving myocardial blood flow in the localised stenotic lesion of the coronary arteries. They say that the low profile enables the kissing...
read full descriptionTerumo's recently launched 0.014" Tercross Angioplasty balloon device has a low balloon crossing profile, hydrophilic coating and it provides reliable crossability. A seamless, polymer shaft offers enhanced pushability, adequate kink resistance and fast deflation times. A wide...
read full descriptionThe Terumo Torque Device accomodates wires with diameters from 0.010 to 0.038 inches.
read full descriptionThe TR Band hemostasis device works by providing controlled compression of the radial artery without completely occluding vessel flow or significantly compressing other structures. The transparent cuff allows precise visual control, and the air injection port and inflator syringe ensures...
read full descriptionWhichMedicalDevice is a FREE resource created by clinicians for clinicians.
Registration is free and gives you unlimited access to all of the content and features of this website.
Find out more...Registration is free and gives you unlimited access to all of the content and features of Which Medical Device. Find out more...
Which Medical Device is a community of clinicians sharing knowledge and experience of the devices and procedures we use on a daily basis. We ask that our members register with us so that we can maintain the unbiased and independent nature of our content. Registration is quick and free.
We do not make your details available to any third parties nor do we send unsolicited emails to our members. You can read our Privacy Policy here.