Angio-Seal

Added Apr 27, 2008

Manufactured and Distributed by Terumo

Editor Rating

info

User Rating

info
Add your Rating

Description

From Which Medical Device

Angio-seal is a medical device indicated for use in closing and reducing time to hemostasis at the femoral arterial puncture site in patients who have undergone diagnostic angiography procedures or interventional procedures (minimal artery diameter of 4mm).

The 6F Angio-Seal device is for closure after usage of a 6 French or smaller procedural sheath, while the 8F Angio-Seal device is for closure after usage of an 8 French or smaller procedural sheath.

 

Angio-Seal device deployment is easy with only 3 deployment steps:

 
Locate the Artery
 
Insert the Angio-Seal™ locator and sheath system until blood flows through the drip hole
 
  • Withdraw and re-insert to confirm correct location into the vessel
  • Remove the locator and wire, leaving the Angio-Seal™ sheath in place
 
 
Seal the puncture
 
  • Pullback the device until the suture stops
  • Grasp the tube to manually compact until reaching the black marker
  • Confirm hemostasis and cut the suture
  • Insert the Angio-Seal™ locator and sheath system until blood flows through the drip hole
  • Withdraw and re-insert to confirm correct location into the vessel
  • Remove the locator and wire, leaving the Angio-Seal™ sheath in place
 
Set the anchor
 
  • Insert the Angio-Seal™ into the sheath, click

 

PROVEN
 
Angio-Seal is on the market for >20 years, with proven successful device deployment and efficacy in numerous clinical randomised trials:
  • 99.7% deployment success1
  • 97.8% haemostasis by device1
FAST SEALING
 
Angio-Seal provides significant reduction in time to hemostasis and ambulation:2,3,4
• versus manual compression
• versus competitive vascular closure device
 
References
Applegate RJ et al. J Invasive Cardiol. 2010;22(9):420-6. Martin et al. Catheterization and Cardiovascular Interventions 71:1–5 (2008). Duffin et al. .J Invasive Cardiol. 2001 May;13(5):354-62 Deuling et al. Catheterization and Cardiovascular Interventions 71:518–523 (2008)
 
 
Item Reference French size Guidewire diameter (in)

610132

6 0.035
610133 8 0.038
 
 
 

 

Angio-Seal™ VIP Vascular Closure Device (terumo-europe.com)

 

 

 

Have you used this device?

Your opinion matters to others - rate this device or add a comment

WhichMedicalDevice is a FREE resource created by clinicians for clinicians.

Registration is free and gives you unlimited access to all of the content and features of this website.

Find out more...

Please sign in to view this content...